Specifications

Frost Fighter Indirect Fuel Oil, Diesel, Kerosene, JP5, JP8 Fired Heater 500,000 Btu 120v 25 amp

IDF500HS-Oil Special Order Ductable up to 50ft, our IDF lineup comes standard with many features designed for safety, performance, and efficiency not found on competitive systems: 

Fully Insulated Jacket, Industrial Grade Beckett Burner (Oil/Diesel), Stainless Steel Heat Exchanger,

Satin Coated Steel, Powder Coated Paint, Environmental Spill-Containment Tank (Oil/Diesel), LED Polarity Lighting, High Limit Safety Switch,

6-Ply Pneumatic wheels, Adaptable Duct Connection, 3-Trials for Ignition

Added Features on HS Model

In addition to all the standard features included in our standard IDF Series, the HS models are equipped with a 6-Bade Fan and 1.5HP motor, which provide 2.3" of static pressure to allow for duct lengths of up to 100ft.

Features:

Standard Lifting Bail Included

Industrial Grade Beckett Burner (Oil/Diesel Version)

Can be configured with 2 x 12" or 1 x 16" Outlet Front Cap

42 US Gallon Environmental Spill Containment Fuel Tank Included (Oil/Diesel Version)

Optional Heat Recovery System Available to Minimize Service Calls (Oil/Diesel Version)

2.3" Static Pressure – Increased duct lengths & pressurization for larger structures (Model IDF500HS Only)

Genisys Controller with Diagnostic Reader (Oil/Diesel Version)

The Frost Fighter is portable and simple to operate - all parts have easy access for quick service and routine maintenance.

With over 35 years of proven reliability and rugged durability even in extreme climates, the Frost Fighter remains a leader for temporary heating needs.

Specifications;

IDS500HS 120V 60Hz Indirect Oil Fired Heater Input 500,000 BTU

IDF500 HS - Fuel Oil, Diesel, JP8, Kerosene Fuel

Capacity: 500,000 BTUs

Comes Standard Double Air Outlets 2x12" Outlets (Single 16" Outlet Available on request)

Heated Air (w/o duct) 3,250 CFM

Static 2.3" WC runs up to 100' of Duct

115 volt, 60 Hz, 25 amp

1.5 HP 25 amp Electric Fan Motor

Heat Rise 200° F - (@50 degree F ambient)

Discharge Temperature 200°F (93.3°C) to 0°F (-17.8°C)

Fuel Type: Fuel Oil, Diesel, JP8, Kerosene Fuel *

42-gallon (158.99 L) Poly Tank with gauge and environmental containment.

Fuel Consumption Rate 3.0 GPH

Nozzle Size 2.50 USGPH 60' B (solid)

Pump Pressure 140 P.S.I Maximum

Approx. Run Time 11 Hours

Exhaust Flue Size 6"

Efficiency 81.0%

Stainless Steel Heat Exchanger

Powder-coated paint finish and fully insulated

16" semi-pneumatic wheels with inner tube (4 ply)

Heater only Dimensions 76.5" L x 27" W x 51" H

This item can only be shipped via LTL Freight due to its weight, size, or fragility.

IDF500HS Oil Ships from Canada - Factory Direct

California Proposition 65 Warning

    IDF500HS-Oil Frost Fighter Indirect Fired Heater 500,000 Btu
    Duct adapter  16” single
    IDF500HS-Oil Frost Fighter Indirect Fired Heater 500,000 Btu